Networking2 min read
The office network checklist we run before quoting a fit-out
Switching, Wi-Fi, structured cabling and what to leave behind for the next tenant. A short checklist that prevents the three most expensive fit-out mistakes.
ARTEK Engineering Team
IT infrastructure & security engineers, Dubai
An office fit-out has a short window and a long tail. The network is usually the last thing scheduled and the first thing everyone notices when it is wrong. We run the same checklist on every survey, because each item maps to a mistake we have had to undo.
The three expensive mistakes
- A single all-in-one router for a floor that has more devices and simultaneous video calls than it can hold. Consumer kit is fine until forty people are on it.
- Wi-Fi planned by hope — access points placed where cabling was easy rather than where people sit, with no survey and no comparison against the building's walls.
- Cabling that no one can label six months later, when a fault on one run means testing every run.
Switching and topology
- Count ports by desk, device and access point — and add headroom for how the team will grow this year, not just today.
- Choose PoE for access points, cameras and phones when the switch is specified, not by adding injectors afterwards.
- Use VLANs to separate guest Wi-Fi, staff devices, cameras and back-office systems. It is the single biggest security win per unit of effort.
Wi-Fi
A Wi-Fi plan starts with a survey of the floor: walls, material, glass partitions and interference. From there, access point count and placement follow, and the plan should be validated after install with a walk test covering the worst seats, lifts and meeting rooms.
Structured cabling
Certified cable, patch panels and every run labelled at both ends. Cabling is hidden, so it is where corners are cut, and every shortcut is expensive later: new runs through finished ceilings, or hours spent tracing a single failed link.
| Item | Minimum | Why |
|---|---|---|
| Cable category | Cat6 or better | Headroom for port speeds and future devices |
| Labelling | Both ends, documented | Fault isolation in minutes, not hours |
| Patch panel | In a lockable cabinet | Protects against accidental disconnects |
| Spare runs | 10–20% | Adds drop points without re-opening ceilings |
Leave the next tenant a favour
As-built drawings, the port map, switch credentials, Wi-Fi plan and the ISP details. A fit-out with that file is worth more to a landlord and survives a change of IT provider. See network solutions for how we scope and deliver this.
Published 4 Sept 2026
ARTEK Engineering Team
Practical guidance from the engineers who survey, install and maintain the systems — written for businesses evaluating the same decisions.